Housing (Size 10 / 15 / 20) | PTFE |
Wetted Parts, Body / Tube | PFA / PFA |
End Cap (Size 04 / 06) | PP |
Cable Fitting | PP |
Cable Jacket | PVC |
Speed of Sound in Fluid | 1000 to 2200 m/s |
Fluid Temperature* | 10 C to 60 C |
Fluid Pressure | 0 to 70 psig |
Fluid Kinematic Viscosity* | 0.5 x 10-6 m2/s to 4.5 x 10-5 m2/s |
Enclosure Classification | IP65 |
Signal Converter Specifications | USC-B01 (without display) & USC-D01 (with display) |
Input Power | 24 Vdc ± 10% |
Power Consumption | 3.3 W Max. Approx @ 140 mA (Continuous) Max. 200 mA, start-up current |
Ambient Power | 0°C to 50°C / 30 ~ 80 RH |
Installation | DIN Rail Mounting |
Enclosure Class | IP 20 (Indoor use) |
Materials | USC-B01 - Polycarbonate |
Weight | USC-B01 - 225 grams / USC-D01 - 530 grams |
EMC | EN61326 |
Sensor Cable | Shielded twisted pair |
Electrical Connection | Pluggable screw terminals, accepts 28 to 16 AWG wire |
Analog Output | Current O/p: Active: 4 to 20 mA (Max. Load < 900 ohms) Passive: 4 to 20 mA (Max. Load < 1200 ohms @ 30 V max.) Voltage O/p: 0 to 10 Vdc (min. impedance > 10 K) |
Pulse Output | Open Collector (sinking)/Max. 30 Vdc, 200 mA max. Pulse (Hz) - 10 KHz max., Configurable Pulse (Volume) - Pulse weight from 0.1 mL to 1000000 Gallons, Configurable |
Digital Output | Open Collector / Max. 30 Vdc, 200 mA max. two digital Output configurable for Low flow rate/High flow rate/Totalizer greater than/Totalizer less than/Signal strength less/Positive totalizer pulse LED Alarm indication |
Digital Input | Zeroing - Momentarily pull-up to 24Vdc for activation Totalizer Reset - Contact closure or Vdc pull-up (5 Vdc max) |
Low Flow Cut-off | Configurable |
Linearization | Max. 14 points (Configurable) |
Display (optional) | LCD: 2 line 16 digits alpha numeric (with backlight) with LED alarm indication |
Digital Communication | RS 485 and RS 232 |